b) The cell must be horizontal with the unions facing downward. The cell must be level in
order for the flow sensor to function properly.
c) Note that the water can flow through the cell in either direction.
d) Glueing: The cell unions are moulded ABS polymer. They can be glued to PVC using
PVC cement. First clean both surfaces with solvent cleaner then apply glue to both
surfaces. Assemble glued joint and hold in place for at least 30 seconds. Allow 24 hours
to set before turning on the circulation system.
Water pressure in the cell must not exceed 200kPa (29 psi). Temperature of water in cell must
not exceed 40ºC (104º F).
CAUTION: Do not fit isolating valves at both ends of cell. Cell will break if one or both valves
are closed. If pool equipment is below water level call Zodiac Pool Care Canada at
1 888 647-4004 for further instruction on isolating the cell for service needs.
3. Install the power pack
Determine the proper area to mount the power pack:
- Position at least 3 metres (10 feet) horizontally away from pool or a hot tub.
- Place power pack close enough to the cell for the cell leads to reach. There is 1.8
metres (6 feet) of cell lead. A lead extension kit can be purchased through Zodiac Pool
Care Canada to add another 1.8 metres (6 feet). IMPORTANT: No more than one lead
extension may be added.
- Power pack must not be installed directly above any other heat source such as filter,
pump or heater. It must be at least 30 cm (1 foot) from the ground to allow free
circulation or air around it.
- Do not enclose the power pack in a box.
- A shaded position away from rain and direct sunlight is preferable, though not essential.
Mount the powerpack to a wall or post using the screws provided. If the power pack is to be
installed on a post, first install on a flat panel of suitable waterproof material at least 24 cm
(9.45 inches) wide by 44 cm (17.32 inches) high then attach to post.
To reduce the risk of electric shock it is recommended that pools be bonded. Two bonding lugs
are provided on the external surface of the power pack. One lug is located at the bottom of the
enclosure and the second is located at the side. Connect the local common bonding grid in the
area of the swimming pool to these terminals with a bare copper wire not smaller than 6 AWG.
4. Connecting the power pack to the cell
Connect the blue sensor wire clip to the blue sensor terminal and the other 2 wires to either
terminal on the cell. It does not matter which one goes where. Check that the terminals are a
snug fit.
Keep the cell terminals protected with a light coating of silicone grease to allow for a positive
electric connection. Use of any other type of grease may damage the terminal seals and ‘o’ rings.
INSTALLATION INSTRUCTIONS