Cloud LM-2 Series Manual de instalación Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 36
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
Chlorinator Maintenance
Winterizing
When closing the pool for the winter, perform the following additional steps to winter-
ize your Clearwater salt chlorinator.
1. Turn off the power to the Clearwater at the circuit breaker.
2. Remove the Clearwater cell by unthreading the quick disconnect unions and
removing the three wires from the cell. Inspect the cell for calcium deposits and
clean if necessary with a solution of 1 part muriatic acid and 10 parts water (see
“How to clean your cell”).
3. Coil the wires and wrap them in a plastic bag to prevent corrosioin over the
winter. Tape the bag to the power pack.
4. Insert expandable plugs (available from your pool professional) into upright
plumbing lines where the cell was connected.
5. Store the Clearwater cell indoors for the duration of the winter.
How to clean your cell.
In unusual situations, the self cleaning electrodes may benefit from occasional manual
cleaning to remove scale build-up as the result of having very “hard” water or continu-
ous high pH conditions, which can occur with new plaster finishes.
1. Switch off the filter pump and chlorinator, close necessary valves. Note: Always
turn pump off prior to installing or removing any Clearwater cell. Your
pump / filter system is operated under pressure and pressure must be
released before you begin. Open the air relief valve on your pool filter to
release the pressure in the system.
2. Unplug the leads from the cell terminals.
3. Undo the two barrel unions joining the cell housing to the pool filtration system
and carefully remove the cell housing. Lay the housing upside down on a flat surface
with the inlet ports on top.
34
CHLORINATOR MAINTENANCE
Vista de pagina 33