CONTROLLER OPERATION
Controller Operation
Startup
When switched on, the chlorinator must go through an initialization sequence; this is indicated by the
amber LED being illuminated. After a short period the LED will switch off and the chlorinator will
begin ‘normal’ operation.
First time startup
When the chlorinator is connected to the mains for the first time and the initialization sequence has
been completed the chlorinator defaults to the ‘zero output’ state. The user can then select the
desired output level.
Output Settings
The battery backup will hold the output settings in memory when the unit is turned off, unless the
setting was changed less than one minute before turning off.
Reversing Polarity
The battery backup will remember the polarity reversal time.
Controller Interface
Because the LM2 chlorinator is capable of being connected to various controllers, it is necessary to
select which controller the LM2 is to be connected to. This is done as follows:
1. Make a suitable cable connection.
2. Turn the power to the LM2 ‘ON’ via the controller.
3. HOLD the LM2 “service” button down for at least 20 seconds (see illustration below). The Super
Chlorinate LED will flash momentarily, either 1, 2 or 3 times, then will go out for approximately 5
seconds.
4. Continue to hold the “service” button down until the correct number of flashes for the controller
being used is observed. See the controller chart below.
Hidden “Service” Button here