INDICATOR LIGHTS - WHAT THEY MEAN
Indicator lights: What they mean
Chlorine Output
A series of six lights indicate the chlorine output setting of the power pack. More
lights equals greater chlorine production. Note: This setting does not show the actual
chlorine reading in the pool. Use of a test kit is required to confirm the free chlorine
reading of pool water.
Chlorine Output – Yellow Light Flashing
The yellow (low output) light flashes for a few minutes during cell reversal (cell
self-clean) indicating no output during this time.
Super Chlorinate – Light On
This light indicates that the super chlorinate feature has been selected, it will turn off
when the super chlorinate period has ended.
Super Chlorinate – Light Off
Function not selected.
Add Salt – Light On
The ‘Add Salt’ light will come on at any salt level between 3000ppm and 4000ppm
depending on mains voltage and water temperature (below 18ºC, 65ºF). This is not
a fault but a precaution to ensure the salt level is never too low. (See “Salt: When and
how to add it’). Note: Operating the LM2 at reduced salt levels may shorten the life
of the cell.
Add Salt – Light Off
Indicates that the salt level in the pool is correct.
No Flow – Light On
This indicates insufficient water flow in cell, usually caused by the pump not running.
The chlorine output will also turn off at this time. Do not leave the device on when
the pump is off or when backwashing the filter.
All Lights Off
All lights off indicates the LM2 is turned off. Turn unit on. If lights are still off, check
the resettable fuse and circuit breaker.