CONTROLLER OPERATION
Polaris Eos: “Check Chlorinator” “0ppm Salt”
Jandy Aqualink RS (REV “K”): “0ppm Salt”
Jandy Aqualink RS (REV “L”): “No Flow
Pentair IntelliTouch: “Check Flow/PCB”
Test button
Due to the “service” button being used for selecting the controller as well as to test the polarity
reversal, it is important to avoid holding the “service” button for more than 15 seconds when testing
or the controller selection may be altered. If this occurs the controller selection can be reset by
following the procedure outlined in the section called “Controller Selection”.
Safety features
The ‘Chlorine Output’ lights indicate that the chlorinator is operating correctly and producing
chlorine. In the event of hydrogen gas accumulation in the cell housing (for example, when the
plumbing valve settings are positioned incorrectly), the chlorinator will cease producing chlorine for
safety reasons. The pool pump will continue to operate as normal. (See Safety Test).
The ‘Add Salt’ light warns the pool operator that the salt concentration in the pool has dropped
below a preset critical value. More salt should be added. See the accompanying Owner’s Manual for
guidelines as to the addition of salt. Note: the ‘Add Salt’ light may activate if the water temperature
of the pool drops to temperatures below 18°C (65°F) or if the cell is damaged or needs replacement.
Consult Zodiac Pool Care or your local Clearwater dealer for details.
Safety test
It is essential that the flow failure system be tested by the following method. Switch on the pump and
chlorinator, and adjust the chlorine output to maximum. Disconnect the blue sensor lead clip from
the terminal pin at the end of the cell. The red ‘Low Flow’ light should come on and the ‘Chlorine
Output’ lights will drop to minimum, yellow light, showing that no chlorine is being produced.
This check should confirm that the flow failure system is operating correctly.
Reconnect the sensor lead clip to the terminal pin which will cause the chlorinator to resume normal
operation. Do not continue to operate the chlorinator if the test of the flow failure system indicates
a fault. Contact Zodiac Pool Care for advice.