6.6 Microphone Level Controls
Each zone has separate front panel mounted level controls for Mic 1 and Mic 2. The level
controls allow the user to adjust the microphone signals to a suitable level in any zone; rotating
any Mic level control fully anti-clockwise effectively turns the microphone off.
All microphone signals are routed directly to the respective power amplifier stage, and are
therefore totally unaffected by the music controls and line 6 priority. Mic 1 and Mic 2 rear panel
gain controls should be set to a level where it is not possible to have excessive gain even when
the front panel level controls are fully clockwise.
6.7 Microphone Priority
Independent, automatic voice operated priority is provided so that when a microphone is used,
the music signals will attenuate by approximately 30dB; after the announcement, the music
signals will restore smoothly to their former level. If microphone over music priority is not desired
set internal jumper J12 to the 'OFF' position. PCB location of jumper J12 is shown below: -
A second microphone priority allows the signals of Mic 1 to mute those of Mic 2. This Mic 1 over
Mic 2 priority in each zone can be defeated by removing a diode from the PCB; D30 for Zone 1,
D25 for Zone 2, D22 for Zone 3, and D19 for Zone 4.
When removing diodes D19, D22, D25 or D30 or setting jumper J12 please ensure that you:
• Remove the mains cable from the rear of the product before removing the top
panel.
• Only reassemble the unit using screws identical to the original parts.
8
V6 070113
Location of Jumper J12
Location of D19, D22, D25, and D30.