LM-2 Installation Guide v1.06
The LM-2’s OUTPUT connector should be connected to the host unit’s FACILITY PORT for the Zone in which it is installed*
with screened Cat 5 cable and shielded RJ45 plugs.
LINK
OUTPUT
LM-2 (UK version illustrated)
100 m max
Connect to
OUTPUT socket
Connect to
FACILITY PORT
Screened
Cat 5 cable
The maximum total Cat 5 cable length should not exceed 100 m. If further modules are being “linked” together (see below),
this gure applies to the overall cable run from the host unit to the “furthest” module in the chain.
IMPORTANT: Because the cables carry low-level audio, only screened Cat 5 should be used, the foil screen of the cable being
bonded to the metal screening can of the plugs. If an LM-2 is being installed in very close proximity to the host unit, it may be
possible to use ready-made screened Cat 5 “patch” cables of short length. In all other situations, shielded RJ45 plugs should be
crimped onto the installed screened Cat 5 cable using the pinout shown below.
PIN USE Cat 5 CORE
1 Audio ‘cold’ phase (-) White + Orange
2 Audio ‘hot’ phase (+) Orange
3 Priority VCA control White + Green
4 +15 V Blue
5 0 V White + Blue
6 -15 V Green
7 Music level control (0 to 10 V) White + Brown
8 Music source select control (0 to 10 V) Brown
SCN Screen for system music controls Connector shell
* There is no reason why the module cannot be connected to the Facility Port of a Zone other than that in which it is installed – though this is likely to be an
unusual installation scenario.
 
