15 General Specifications
Inputs Balanced via 3 pin XLR type connector.
Outputs Binding Posts for flexible cables up to 2.5mm²
Protection VI limiting, DC offset, Thermal and Switch-on Delay
Status Indicators LED indicators on each channel for Signal, Peak & Protect
Cooling Force cooled using a two speed DC fan.
Dimensions 482.6mm x 88.0mm (2U) x 325.0mm deep (+ connectors)
Weight 10kg net
16 Technical Specifications
Rated output 120 watts/4 ohm load 85 watts/8 ohm load
Bridged Output 240 watts/8 ohm load
Frequency Response ±1dB 10Hz to 50kHz
THD <0.005% 1kHz <0.05% 20Hz/20kHz 8 1dB below rated
output
VCA Module THD <0.03% 20Hz/20kHz
Input Sensitivity 0dBu (775mV)
Input Impedance 10k balanced / 5k unbalanced
Noise >90dB below rated output
Slew Rate 35V/µS (power amplifier)
Power Input 230V ±5% (115V ±5% available)
Fuse rating 230V - T5A H 115V - T10A H
This product conforms to the following European EMC Standards
:
BS EN 55103-1:1997
BS EN 55103-2:1997
This product has been tested for use in commercial and light industrial environments. If the equipment
is used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to
railways, transmitters, overhead power lines etc. the performance of the unit may be degraded.
The product conforms to the following European electrical safety standard.
BS EN 60065:1998
15-07-02 V8