CX-A450:
Installation and Operation Manual 7
07-03-05 V3.0
15 Equalisation Module Installation
1. Turn the power off and remove the mains lead.
2. Remove the top panel from the unit.
3. Select the required PCB connector (see list below) that
you wish to install the equalisation module to and
remove the bypass jumper adjacent to it.
Ch 1 CON 6 J5
Ch 2 CON 7 J6
Ch 3 CON 9 J7
Ch 4 CON 10 J8
4. Configure the relevant 65Hz filter to ‘ON’ (See section
7)
5. Fit the EQ card to the connector so that the module
board is perpendicular to the main board.
6. Push down on the EQ card until it locates with a click.
7. Replace the top panel.
NOTE #1: Before installing your optional modules, ensure
that the total power requirement does not exceed the limits
of the CX-A450 (see section 10).
NOTE #2: Each channel of the CX-A450 can have both
the VCA-5 module and Bose
EQ card installed at the
same time.
16 Field Servicing
The CX-A450 is ruggedly built and uses proven reliable
circuitry. It requires no more than the occasional removal
of any dust that may have built up inside the unit because
of the forced cooling.
17 General Specifications
Inputs Balanced via 3-pin plug-in screw terminal type connectors
Outputs 2-pin plug-in screw terminal type connectors for flexible cables up to 2.5mm²
Protection VI limiting, DC offset, Thermal, Switch-on Delay & Dynamic Clipping Protection
Status Indicators LED indicators on each channel for Signal, Peak &Protect
Cooling Force cooled using variable speed DC fan
Dimensions 482.6mm x 88.0mm (2U) x 300.0mm deep (+ connectors)
Weight 7.15kgs
18 Technical Specifications
Rated Output 4 Ohm load(s) 50W nominal
Rated Output 8 Ohm load(s) 35W nominal
Bridged Output 100W nominal into 8 Ohm load, minimum load 8 Ohms
100V Output 40W into 250 Ohms
70V Output 40W into 125 Ohms
Frequency Response +0dB –0.5dB 10Hz to 20kHz, switch-able high pass filter –3dB @65Hz
THD+N 0.02%, typical, @1kHz, 60W into 4 Ohms, one channel driven,
measurement BW 22Hz to 80kHz
Fig 12